CDMXV - ACTIVATOR W

Product Identification

Product ID:ACTIVATOR W
MSDS Date:01/10/1995
FSC:8040
NIIN:01-032-9205
MSDS Number: CDMXV

Responsible Party
RESIN TECHNOLOGY GROUP INC, ARMSTRONG PRODUCTS DIV
28 NORFOLK AVENUE
SOUTH EASTON, MA 02375
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 508-230-8070

Cage: 0JVX9

Contractor
RESIN TECHNOLOGY GROUP INC
S EASTON, MA 02375 US

Telephone: 508-230-8070

Cage: 0JVX9

Ingredients

(ORAL, RAT) 2500 MG/KG

CAS: 112-24-3

RTECS: YE6650000

OSHA PEL N/K

ACGIH TLV: N/K


THIS INFO IS IN REGARD TO PURE FORM OF COMPONENT.

RTECS: 9999999ZZ


IS SUGGESTED THIS INFO BE INTERPRETED BY PERSONS

RTECS: 9999999ZZ


EYES & SKIN, POSS RSLTG IN SEV BURNS. INHAL OF

RTECS: 9999999ZZ


CAN BE ABSORBED THRU SKIN. POSS SKIN & RESP

RTECS: 9999999ZZ


IRRIT OF GI TRACT. REPRO EFTS MAY RSLT. EFTS ON

RTECS: 9999999ZZ


PREGNANT GPG. LIVER & KIDNEY DMG & KIDNEY & BRAIN

RTECS: 9999999ZZ


MUTAGENICITY ASSAY BOTH WITH & WITHOUT ACTIVATION.

RTECS: 9999999ZZ


OF OVEREXPOSURE & SHOULD TAKE APPROPRIATE

RTECS: 9999999ZZ


INHALED, REMOVE TO FRESH AIR. ADMIN OXYGEN

RTECS: 9999999ZZ


OBTAIN MED ATTN W/OUT DELAY. UNDER NORM CNDTNS, NO

RTECS: 9999999ZZ


INDUCE VOMIT. SEEK IMMED MED ATTN; CALL POIS CTL

RTECS: 9999999ZZ


OF WATER TO DRINK. DO NOT GIVE CARBONATED DRINKS.

RTECS: 9999999ZZ


MOUTH, PHARYNX, ESOPHAGUS & STOMACH. THERE IS

RTECS: 9999999ZZ


SUCH AS FULLER'S EARTH, CLAY OR OTHER APPROP

RTECS: 9999999ZZ


& DISPOSAL. OBSERVE ALL FEDERAL, STATE & LOCAL

RTECS: 9999999ZZ


EXHAUST MAY BE REQUIRED TO CONTROL EXPOSURE WHEN

RTECS: 9999999ZZ


& FULL LENGTH FACESHIELD .

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:SEE INGREDIENTS
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE: CNTCT CAUSES SEV IRRIT. CAN CAUSE
INJURY (IE BURNS) TO CORNEA & OTHER TISS. SEVERITY OF RXN DEPENDS
ON DURATION OF EXPOS & PROMPT ADMIN OF PROPER FIRST AID PROCS.
SKIN: CORR; CNTCT CAN CAUSE BURN S & SEV TISS DMG. HARMFUL WHEN
ABSORBEDTHRU SKIN IN SUFFICIENT AMTS. CNTCT CAN CAUSE DEVELOPMENT
OF (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: HYPERSENS (ALLERGIC RXN) IN
SUSCEPTIBLE PERS. INHAL: CAN CAUSE IRRIT TO NOSE, THROAT & UPPER
RESP TRACT. CAN BE IRRIT TO MUC MEMBS, ESP FOLLOWING PRLNGD EXPOS
TO MISTS/VAPS. INHAL CAN CAUSE DIZZ, HDCH & INCOORD. CAN CAUSE
WHEEZ, COUGH, SHORTNESS OF BRTH & FEELING OF TIGHTNESS IN CHEST.
INGEST: CORR; (SUPDAT)
Medical Cond Aggravated by Exposure:SOME OF COMPONENTS OF PROD MAY
AGGRAVATE EXISTING CNDTNS OF SKIN, RESP SYS, REPRO SYS & IMMUNE SYS
&/OR SPECIFIC ALLERGIES. CONSEQUENTLY, CERTAIN PERS MAY BE MORE
SUSCEPTIBLE TO POSS EFTS (ING 9)

First Aid

First Aid:EYE: FLUSH W/STEADY STREAM OF WATER FOR AT LST 15 MIN. OBTAIN
PROMPT MED ATTN. SKIN: IMMED WASH W/SOAP & PLENTY OF WATER FOR AT
LST 15 MIN. CLEANSE SKIN THOROUGHLY INCL HAIR & UNDER FINGERNAILS.
FOR L G EXPOS USE EMER SHOWER. REMOVE CONTAMDCLTHG & SHOES. LAUNDER
CLOTHES SEPARATELY BEFORE REUSING. DESTROY OR THOROUGHLY CLEAN
SHOES BEFORE REUSING. OBTAIN IMMED MED ATTN. INHAL: IF VAP IS (ING
10)

Fire Fighting

Flash Point Method:COC
Flash Point:>500F,>260C
Extinguishing Media:SM FIRES: USE WATER SPRAY, FOAM, HALON, DRY
CHEMICAL OR CARBON DIOXIDE. LG FIRES: USE WATER SPRAY, FOG OR
ALCOHOL FOAM.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:MAY LIBERATE IRRITATING VAPORS DURING
COMBUSTION OR DECOMPOSITION.

Accidental Release

Spill Release Procedures:VENT AREA IF NEC. EVACUATE IF AIRBORNE LEVELS
COULD EXCEED ESTABLISHED LIMITS. CONTAIN SPILL USING DIKE/BARRIER.
IF SUBSTANTIAL QTY IS SPILLED & CAN BE PUMPED, RECOVER W/PUMPING
EQUIP OR VACUUM TRUCK. OTHERWISE, COVER SPILL W/INERT ABSORBENT
(ING 15)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY, WELL VENTILATED
AREA. DO NOT STORE ABOVE 100F. AVOID CONTACT WITH EYES, SKIN AND
CLOTHING.
Other Precautions:HEATING CAN GENERATE VAPORS; USE APPROPRIATE
VENTILATION OR NIOSH APPROVED RESPIRATORS AS NECESSARY.

Exposure Controls

Respiratory Protection:AVOID BREATHING VAPOR OR MIST. WHERE EXPOSURE
EXCEEDS ESTABLISHED AIRBORNE LIMITS, USE A NIOSH APPROVED
RESPIRATOR OR A SELF-CONTAINED BREATHING APPARATUS OR A SUPPLIED
AIR RESPIRATOR AS NECESSARY TO CONTROL EXPOSURE.
Ventilation:MAINTAIN AIRBORNE CONCS BELOW ESTABLISHED EXPOS LIMS. GEN
VENT MAY BE ACCEPTABLE, HOWEVER, ENCLOSURE & LOCAL (ING 17)
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS (ING 18)
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER . WEAR
PROT CLOTHING (RUBBER BOOTS & APRON) IN ORDER TO PREVENT SKIN
CONTACT.
Work Hygienic Practices:CONTACT LENSES SHOULD NOT BE WORN.
Supplemental Safety and Health
EFTS OF OVEREXP: SWALLOWING CAUSES SEV BURNS TO MOUTH, THROAT & DIGEST
TRACT. CAN CAUSE NAUS, VOMIT & GI UPSET. OTHER:DEPENDING ON ROUTE,
FREQUENCY & DURATION OF EXPOS, FOLLOWING ORGANS &/OR SYS MAY B E
ADVERSE EFFECTED: EYE, SKIN, RESP SYS, REPRO SYS & IMMUNE SYS
(ALLERGIC RXNS). TOXICOLOGICAL INFO: (ING 2)

Chemical Properties

Vapor Pres:<0.01
Vapor Density:>1
Spec Gravity:0.97
Evaporation Rate & Reference:<0.001(N-BUTYL ACETATE=1)
Solubility in Water:SLIGHTLY SOLUBLE
Appearance and Odor:AMBER VISCOUS LIQUID; AMINE ODOR.
Percent Volatiles by Volume:NONE

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS.
Stability Condition to Avoid:STABLE UNDER NORMAL CONDITIONS AND USE.
AVOID CONTACT WITH INCOMPATIBLE CHEMICALS.
Hazardous Decomposition Products:AMINES, OXIDES OF NITROGEN, SMOKE,
SOOT, CARBON DIOXIDE, CARBON MONOXIDE.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE MADE IN ACCORDANCE WITH
APPLICABLE FEDERAL, STATE AND LOCAL GOVERNMENTAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.